{"product_id":"lutron-hqp6-2-homeworks-qs-processor-clearance-open-box","title":"Lutron HQP6-2 - HomeWorks QS Processor - Clearance \/ Open Box","description":"\u003cp\u003e\u003cspan style=\"font-size: 14pt;\"\u003e\u003cstrong\u003eHomeWorks QS Processor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eThe QS processor provides control and communication to HomeWorks system components.\u003c\/p\u003e \u003cp\u003eThe Ethernet links allow communication to the HomeWorks QS software, integration with third party systems and communication between multiple processors. HomeWorks QS processors may be connected using either standard networking or using ad-hoc networking. All processors on a project must be connected to a single network. The HomeWorks QS software and all integration equipment must be connected to the same network as the processors.\u003c\/p\u003e \u003cp\u003eThe processor is powered from the QSPS-DH-1-75 or QSPS-DH-1-60 power supply. Refer to the HomeWorks QS software to determine link power\u003cbr\u003erequirements.\u003c\/p\u003e \u003cp\u003eThe QS processor can be installed in a HQ-LV21, L-LV21, L-LV14, or PNL-8 enclosure.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eProcessor Capabilities\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eEach QS processor has 2 links that can be individually configured as one of four types:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHomeWorks Power Panels\u003cbr\u003e16 interfaces \/ 256 zones\u003c\/li\u003e \u003cli\u003eHomeWorks QS Wired Device Link\u003cbr\u003e99 devices \/ 512 zones\u003c\/li\u003e \u003cli\u003eHomeWorks Clear Connect\u003cbr\u003e99 devices \/ 100 zones\u003c\/li\u003e \u003cli\u003eHomeWorks Wired Dimmers\u003cbr\u003e4 interfaces \/ 192 zones\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cspan style=\"font-size: 14pt;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e HQP6-2\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Processor (P): 24–36 V- 250 mA\u003cbr\u003e             Links (L1 \/ L2): 24–36 V- 2 A per link\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTypical Power Consumption:\u003c\/strong\u003e 5 W; 8 Power Draw Units (PDUs)\u003cbr\u003e                                                   Test conditions: Two Ethernet links connected, both device links in use\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRegulatory Approvals:\u003c\/strong\u003e UL, cUL, CE, NOM\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Indoor use only. 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHeat Generated:\u003c\/strong\u003e 17 BTU\/hr — typical\u003cbr\u003e                              (24 BTU\/hr with 2 links at 2 A each output)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCooling Method:\u003c\/strong\u003e Passive Cooling\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePower Failure Memory:\u003c\/strong\u003e System data stored in non-volatile memory. Timeclock retention for 10 years\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInternal Timeclock:\u003c\/strong\u003e ±1 minute per year\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMiswire Protection:\u003c\/strong\u003e All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLow-Voltage Link Wire Type:\u003c\/strong\u003e Two pair — one pair 18 AWG (0.75 mm2), one pair 18 to 22 AWG\u003cbr\u003e                                                    (0.34 to 0.75 mm2) twisted shielded — IEC PELV \/ NEC® Class 2 cable\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLow-Voltage Power Wire Type:\u003c\/strong\u003e 18 AWG (0.75 mm2)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunications:\u003c\/strong\u003e Ethernet, RS485 (QS, RF, Power Panel)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLink Capacities:\u003c\/strong\u003e HomeWorks Power Panels 16 interfaces\/256 zones\u003cbr\u003e                              HomeWorks QS Wired Device Link 99 devices\/512 zones\u003cbr\u003e                              HomeWorks RF Link 99 devices\/100 zones\u003cbr\u003e                              HomeWorks Wired Dimmers 4 interfaces\/192 zones\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Meets or exceeds the IEC 61000-4-2 standard\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e Meets or exceeds ANSI\/IEEE C62.41 standard\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mounts in HQ-LV21, L-LV14, L-LV21, or PNL-8 enclosure\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e With terminal blocks (as shown): 4.27 in (108 mm) x 6.0 in (152 mm)\u003cbr\u003e                      Without terminal blocks: 4.27 in (108 mm) x 5.26 in (134 mm)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Two 5-pin removable terminal blocks* for Links 1 and 2.\u003cbr\u003e                       One 5-pin removable terminal block* for Power Input.\u003cbr\u003e                       Two RJ45 standard Ethernet connections.\u003cbr\u003e                       *Each terminal will accept up to two 18 AWG (0.75 mm2) wires.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cem\u003e\u003ca href=\"https:\/\/assets.lutron.com\/a\/documents\/369-376_hwqs_processor.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Spec Sheet\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":62788563665055,"sku":"LUT-OBX-HQP6-2","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0495\/6910\/4031\/files\/297fe3e8-f445-45b8-a7e3-7147f31f4729.jpg?v=1778079762","url":"https:\/\/listenup.com\/products\/lutron-hqp6-2-homeworks-qs-processor-clearance-open-box","provider":"ListenUp","version":"1.0","type":"link"}