Similar Products
View More
No items found.
We’ll be happy to e-mail you when this item is available. Just fill in your name and e-mail address
We’ll be happy to e-mail you when this item is available. Just fill in your name and e-mail address
UPS-3000-OL
SurgeX online double conversion standalone UPS battery backup solutions deliver clean continuous power, via online double conversion technology, to ensure the safe shutdown of equipment in the event of an outage. All incoming power is converted from AC to DC and then back to AC. If the main power is interrupted, the batteries are still holding up the incoming DC supply to the inverter, so the load continues to be supplied with absolutely no interruption whatsoever. The zero transfer time guarantees mission critical equipment remains up and running.
The Standalone rack mount UPS backup power solutions in 3000 VA configuration with hot swappable internal batteries ensures maintenance can be performed without powering down connected equipment. The solution has extended scalable runtimes of up to 8 hours via self-charging extended battery packs.
SPECIFICATIONS:
Load Rating: 25A
Voltage Rating: 120V
Power Requirement (No Load): 0
Input/Mains Plug Type: L5-30P
Input/Mains Cord Length: 5'6"
# of Receptacles: 5
Receptacle Type: (1) LF-30R
(4) 5-15/20R
Under-Voltage Auto Shutdown: Yes
Over-Voltage Auto Shutdown: Yes
Over-Current Auto Shutdown: Circuit Breaker
Over-Temperature Auto Shutdown: Internal Temperature Fault Shutdown
Network Port: Optional SNMP Card
Serial Port: RS-232 on Female 9-pin D-Subminiature
USB Type B
RJ-45 on Optional SNMP Card
Temprature Sensor Input: None
BTU/h Max: 1756 BTU/h
Auxiliary Relay Outputs: With optional relay card
Contact Closure Input: EPO and optional relay card
Dimensions: 17.24" W x 26.95" D x 3.39" H
Weight: 81 lbs
Temperature Range: 0C to 40C
Humidity Range: <90% non condensing
Agency Listings: UL 1778
CSA-C22.2 No. 107.1
UPS-3000-OL
SurgeX online double conversion standalone UPS battery backup solutions deliver clean continuous power, via online double conversion technology, to ensure the safe shutdown of equipment in the event of an outage. All incoming power is converted from AC to DC and then back to AC. If the main power is interrupted, the batteries are still holding up the incoming DC supply to the inverter, so the load continues to be supplied with absolutely no interruption whatsoever. The zero transfer time guarantees mission critical equipment remains up and running.
The Standalone rack mount UPS backup power solutions in 3000 VA configuration with hot swappable internal batteries ensures maintenance can be performed without powering down connected equipment. The solution has extended scalable runtimes of up to 8 hours via self-charging extended battery packs.
SPECIFICATIONS:
Load Rating: 25A
Voltage Rating: 120V
Power Requirement (No Load): 0
Input/Mains Plug Type: L5-30P
Input/Mains Cord Length: 5'6"
# of Receptacles: 5
Receptacle Type: (1) LF-30R
(4) 5-15/20R
Under-Voltage Auto Shutdown: Yes
Over-Voltage Auto Shutdown: Yes
Over-Current Auto Shutdown: Circuit Breaker
Over-Temperature Auto Shutdown: Internal Temperature Fault Shutdown
Network Port: Optional SNMP Card
Serial Port: RS-232 on Female 9-pin D-Subminiature
USB Type B
RJ-45 on Optional SNMP Card
Temprature Sensor Input: None
BTU/h Max: 1756 BTU/h
Auxiliary Relay Outputs: With optional relay card
Contact Closure Input: EPO and optional relay card
Dimensions: 17.24" W x 26.95" D x 3.39" H
Weight: 81 lbs
Temperature Range: 0C to 40C
Humidity Range: <90% non condensing
Agency Listings: UL 1778
CSA-C22.2 No. 107.1
placeholder