Skip to content
We are available Mon-Sat 9am-6pm MST 1-877-744-1179
Trade/Sell Your Gear
Notify Me When In Stock

We’ll be happy to e-mail you when this item is available. Just fill in your name and e-mail address

Product Description

Line Circle
The Lutron LOS-CIR-450-WH is a white, ceiling-mounted passive infrared (PIR) occupancy sensor with a 450 square feet coverage area and a 360° field of view.
Get the Details

Features & Specs Line Circle

Sensor Type:
Passive Infrared (PIR) with a semiconductor heat detector and multi-zone optical lens.
Coverage Area:
450 sq. ft. (42 m²); ideal for ceilings 8 to 12 feet high.
Operating Voltage:
20–24 VDC, PELV (Class 2: USA) low-voltage, 33 mA nominal current
Dimensions:
4.5 inches in Diameter and 1.4 inches in Height.
Integration:
Can integrate into larger Lutron systems (such as Quantum, myRoom, and Grafik Eye QS) or operate stand-alone using a compatible low-voltage power pack.
Sensor Type:
Passive Infrared (PIR) with a semiconductor heat detector and multi-zone optical lens.
Coverage Area:
450 sq. ft. (42 m²); ideal for ceilings 8 to 12 feet high.
Operating Voltage:
20–24 VDC, PELV (Class 2: USA) low-voltage, 33 mA nominal current
Dimensions:
4.5 inches in Diameter and 1.4 inches in Height.
Integration:
Can integrate into larger Lutron systems (such as Quantum, myRoom, and Grafik Eye QS) or operate stand-alone using a compatible low-voltage power pack.
Expert Insights Coming Soon
Line Circle

Details

Line Circle

LOS-CIR-450-WH Infrared Ceiling Mount Sensor

The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack.
The sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. The detector is sensitive to the heat emitted by the human body. In order to trigger the sensor, the source of heat must move from one range of detection to another. Non-moving hot objects will not cause the lights to turn on.

Features

  • Intelligent, continually adapting Passive Infrared (PIR) sensor
  • Passive Infrared (PIR) sensing
  • Reliable motion detection with high error immunity
  • Snap-locks to ceiling-mounted cover plate
  • Non-Volatile Memory: settings saved in protected memory are not lost during power outages
  • 450 ft2 to 1500 ft2 (42 m2 to 140 m2) coverage when mounted on an 8 ft to 12 ft (2.4 m to 3.7 m) ceiling
  • Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a Lutron system.

Self-Adaptive Feature

The LOS-CIR Series sensors provide reliable detection with high error immunity. The internal microprocessor analyzes the information from the PIR technology and determines the optimum setting to use in order to properly cover the space.

Specifications

Regulatory Approvals

  • UL and cUL listed

Power

  • Operating voltage: 20 – 24 V-, IEC PELV/NEC Class 2
  • Operating current: 33 mA nominal
  • Control output: 20 – 24 V- active high logic control signal with short-circuit protection, open collector when unoccupied

Environment

  • Temperature: 32 °F to 104 °F (0 °C to 40 °C)
  • Relative humidity: less than 95%, non-condensing
  • For indoor use only

Timer Adjustment

  • Automatic mode: Continually adapting sensor automatically adjusts settings to the space
  • Manual mode: 8 to 30 minutes
  • Test mode: 8 seconds

LED Lamp

  • Red: infrared motion detected

Housing

  • Rugged, high-impact, injection-molded plastic
  • Color-coded leads 6 in (15 cm)

Adaptive Functions

  • Installation: 60 minutes
  • Learning: 4 weeks for response to error conditions, air current adaptation, and timer optimization
  • Post-learning occupancy periods
    • 24 hour circadian occupancy periods learned
    • Weekly occupancy periods learned
  • Adjustments in post-learning period
    • Generally occupied periods (threshold = high-sensitivity mode)
    • Generally unoccupied periods (threshold = miser mode)

Reviews

Product Descriptiondown arrow

Product Description

Line Circle
The Lutron LOS-CIR-450-WH is a white, ceiling-mounted passive infrared (PIR) occupancy sensor with a 450 square feet coverage area and a 360° field of view.
Get the Details
Features & Specsdown arrow

Features & Specs Line Circle

Sensor Type:
Passive Infrared (PIR) with a semiconductor heat detector and multi-zone optical lens.
Coverage Area:
450 sq. ft. (42 m²); ideal for ceilings 8 to 12 feet high.
Operating Voltage:
20–24 VDC, PELV (Class 2: USA) low-voltage, 33 mA nominal current
Dimensions:
4.5 inches in Diameter and 1.4 inches in Height.
Integration:
Can integrate into larger Lutron systems (such as Quantum, myRoom, and Grafik Eye QS) or operate stand-alone using a compatible low-voltage power pack.
Sensor Type:
Passive Infrared (PIR) with a semiconductor heat detector and multi-zone optical lens.
Coverage Area:
450 sq. ft. (42 m²); ideal for ceilings 8 to 12 feet high.
Operating Voltage:
20–24 VDC, PELV (Class 2: USA) low-voltage, 33 mA nominal current
Dimensions:
4.5 inches in Diameter and 1.4 inches in Height.
Integration:
Can integrate into larger Lutron systems (such as Quantum, myRoom, and Grafik Eye QS) or operate stand-alone using a compatible low-voltage power pack.
Expert Insightdown arrow
Expert Insights Coming Soon
Line Circle
Detailsdown arrow

Details

Line Circle

LOS-CIR-450-WH Infrared Ceiling Mount Sensor

The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack.
The sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. The detector is sensitive to the heat emitted by the human body. In order to trigger the sensor, the source of heat must move from one range of detection to another. Non-moving hot objects will not cause the lights to turn on.

Features

  • Intelligent, continually adapting Passive Infrared (PIR) sensor
  • Passive Infrared (PIR) sensing
  • Reliable motion detection with high error immunity
  • Snap-locks to ceiling-mounted cover plate
  • Non-Volatile Memory: settings saved in protected memory are not lost during power outages
  • 450 ft2 to 1500 ft2 (42 m2 to 140 m2) coverage when mounted on an 8 ft to 12 ft (2.4 m to 3.7 m) ceiling
  • Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a Lutron system.

Self-Adaptive Feature

The LOS-CIR Series sensors provide reliable detection with high error immunity. The internal microprocessor analyzes the information from the PIR technology and determines the optimum setting to use in order to properly cover the space.

Specifications

Regulatory Approvals

  • UL and cUL listed

Power

  • Operating voltage: 20 – 24 V-, IEC PELV/NEC Class 2
  • Operating current: 33 mA nominal
  • Control output: 20 – 24 V- active high logic control signal with short-circuit protection, open collector when unoccupied

Environment

  • Temperature: 32 °F to 104 °F (0 °C to 40 °C)
  • Relative humidity: less than 95%, non-condensing
  • For indoor use only

Timer Adjustment

  • Automatic mode: Continually adapting sensor automatically adjusts settings to the space
  • Manual mode: 8 to 30 minutes
  • Test mode: 8 seconds

LED Lamp

  • Red: infrared motion detected

Housing

  • Rugged, high-impact, injection-molded plastic
  • Color-coded leads 6 in (15 cm)

Adaptive Functions

  • Installation: 60 minutes
  • Learning: 4 weeks for response to error conditions, air current adaptation, and timer optimization
  • Post-learning occupancy periods
    • 24 hour circadian occupancy periods learned
    • Weekly occupancy periods learned
  • Adjustments in post-learning period
    • Generally occupied periods (threshold = high-sensitivity mode)
    • Generally unoccupied periods (threshold = miser mode)

Reviewsdown arrow

Reviews

View More