Lutron LOS-CIR-450-WH Infrared Ceiling Mount Occupancy Sensor with 450 SQ Ft. Coverage (White) - Clearance / Open Box
Lutron LOS-CIR-450-WH Infrared Ceiling Mount Occupancy Sensor with 450 SQ Ft. Coverage (White) - Clearance / Open Box
We’ll be happy to e-mail you when this item is available. Just fill in your name and e-mail address
We’ll be happy to e-mail you when this item is available. Just fill in your name and e-mail address
Product Description
Get the Details
Features & Specs
Details
LOS-CIR-450-WH Infrared Ceiling Mount Sensor
The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack.
The sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. The detector is sensitive to the heat emitted by the human body. In order to trigger the sensor, the source of heat must move from one range of detection to another. Non-moving hot objects will not cause the lights to turn on.
Features
- Intelligent, continually adapting Passive Infrared (PIR) sensor
- Passive Infrared (PIR) sensing
- Reliable motion detection with high error immunity
- Snap-locks to ceiling-mounted cover plate
- Non-Volatile Memory: settings saved in protected memory are not lost during power outages
- 450 ft2 to 1500 ft2 (42 m2 to 140 m2) coverage when mounted on an 8 ft to 12 ft (2.4 m to 3.7 m) ceiling
- Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a Lutron system.
Self-Adaptive Feature
The LOS-CIR Series sensors provide reliable detection with high error immunity. The internal microprocessor analyzes the information from the PIR technology and determines the optimum setting to use in order to properly cover the space.
Specifications
Regulatory Approvals
- UL and cUL listed
Power
- Operating voltage: 20 – 24 V-, IEC PELV/NEC Class 2
- Operating current: 33 mA nominal
- Control output: 20 – 24 V- active high logic control signal with short-circuit protection, open collector when unoccupied
Environment
- Temperature: 32 °F to 104 °F (0 °C to 40 °C)
- Relative humidity: less than 95%, non-condensing
- For indoor use only
Timer Adjustment
- Automatic mode: Continually adapting sensor automatically adjusts settings to the space
- Manual mode: 8 to 30 minutes
- Test mode: 8 seconds
LED Lamp
- Red: infrared motion detected
Housing
- Rugged, high-impact, injection-molded plastic
- Color-coded leads 6 in (15 cm)
Adaptive Functions
- Installation: 60 minutes
- Learning: 4 weeks for response to error conditions, air current adaptation, and timer optimization
- Post-learning occupancy periods
- 24 hour circadian occupancy periods learned
- Weekly occupancy periods learned
- Adjustments in post-learning period
- Generally occupied periods (threshold = high-sensitivity mode)
- Generally unoccupied periods (threshold = miser mode)
Reviews
Product Description
Product Description
Get the Details
Features & Specs
Features & Specs
Expert Insight
Details
Details
LOS-CIR-450-WH Infrared Ceiling Mount Sensor
The LOS-CIR Series passive infrared ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack.
The sensor uses a small semiconductor heat detector that resides behind a multi-zone optical lens. The detector is sensitive to the heat emitted by the human body. In order to trigger the sensor, the source of heat must move from one range of detection to another. Non-moving hot objects will not cause the lights to turn on.
Features
- Intelligent, continually adapting Passive Infrared (PIR) sensor
- Passive Infrared (PIR) sensing
- Reliable motion detection with high error immunity
- Snap-locks to ceiling-mounted cover plate
- Non-Volatile Memory: settings saved in protected memory are not lost during power outages
- 450 ft2 to 1500 ft2 (42 m2 to 140 m2) coverage when mounted on an 8 ft to 12 ft (2.4 m to 3.7 m) ceiling
- Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a Lutron system.
Self-Adaptive Feature
The LOS-CIR Series sensors provide reliable detection with high error immunity. The internal microprocessor analyzes the information from the PIR technology and determines the optimum setting to use in order to properly cover the space.
Specifications
Regulatory Approvals
- UL and cUL listed
Power
- Operating voltage: 20 – 24 V-, IEC PELV/NEC Class 2
- Operating current: 33 mA nominal
- Control output: 20 – 24 V- active high logic control signal with short-circuit protection, open collector when unoccupied
Environment
- Temperature: 32 °F to 104 °F (0 °C to 40 °C)
- Relative humidity: less than 95%, non-condensing
- For indoor use only
Timer Adjustment
- Automatic mode: Continually adapting sensor automatically adjusts settings to the space
- Manual mode: 8 to 30 minutes
- Test mode: 8 seconds
LED Lamp
- Red: infrared motion detected
Housing
- Rugged, high-impact, injection-molded plastic
- Color-coded leads 6 in (15 cm)
Adaptive Functions
- Installation: 60 minutes
- Learning: 4 weeks for response to error conditions, air current adaptation, and timer optimization
- Post-learning occupancy periods
- 24 hour circadian occupancy periods learned
- Weekly occupancy periods learned
- Adjustments in post-learning period
- Generally occupied periods (threshold = high-sensitivity mode)
- Generally unoccupied periods (threshold = miser mode)